12V 55AH DEEP CYCLE BATTERY N40 SIZE...

Dimensions are 229mm x 138mm x 212mm...

Designed for over 1800 cycles@30%DOD.

Completely sealed with no gassing or maintenance.Totally spillproof.... FULLRIVER BATTERY is a privately owned company, and is one of the largest Valve Regulated Sealed Lead Acid Battery manufacturers in Asia.... FULLRIVER BATTERY currently supplies its full-line VRLA battery products to customers in North America, South America, Asia, Europe, Middle East, and North Africa, and now Australia.FULLRIVER BATTERY has made endeavors since day one to comply with international quality, manufacturing, and environmental standards.They have obtained major international certificates in product quality management and manufacturing process. CERTIFICATIONS: ISO9001 . UL (USA)Number: MH27867.. CE (Europe)Number: G4M201014-0412-E-16..

They are designed and built tough, and will take an enormous pounding. They are designed to withstand shock and vibration better than any standard batteryThe DC range has firmly placed Fullriver as the industries best known and trusted brand that set the standard that everyone else tries to copy when used in cyclic applications such as: Caravans, RV, Scooters, Golfcaddies, Floor scrubbers, Electric outboard motors, Solar, 4WD,Marine power etc. The DC series is also suitable as a dual purpose engine start & deep cycle for Marine usage

DC55-12 Deep-Cycle AGM Battery

Cycling Capacity
20 hour rate 55 Amp Hours
Reserve Capacity
@ 25 Amps 96 minutes @ 75 Amps 21 minutes
Mechanical Specifications
Group Size 22NF
Terminal Type M6
Total Height 8.35" (212 mm)
Height 8.19" (208 mm)
Width 5.43" (138 mm)
Length 9.02" (229 mm)
Weight 39.0 lbs (17.7 kg)
Case Type ABS Plastic - Flame Res Rating UL94-HB
Discharge Table (Constant Current)
Time Amps Rate
20 hr 2.75 0.05 CA
10 hr 5 0.1 CA
8 hr 6 0.13 CA
5 hr 8.7 0.25 CA
3 hr 12.5 0.33 CA
2 hr 16.6 0.5 CA
1 hr 31.3 1 CA
Electrical Specifications
Nominal Voltage 12 Volt
Capacity @ 100 hour rate 61 AH
Capacity @ 20 hour rate 55 AH
Capacity @ 10 hour rate 50 AH
Capacity @ 5 hour rate 45 AH
CCA 400
CA or MCA 480
Short Circuit Current 1160 Amps
Internal Resistance 8m Ω
Charge Voltages
  Battery Voltages
Charge Stage 12V 24V 36V 48V
Bulk 14.7 V 29.4 V 44.1 V 58.8 V
Absorption 14.7 V 29.4 V 44.1 V 58.8 V
Float 13.6 V 27.2 V 40.8 V 54.6 V
TC Factor: -4mV/°C/cell
Temperature Range Specifications
Condition Recommended Maximum
Storage -15°C to 50°C -40°C to 71°C
Operation -15°C to 40°C -40°C to 71°C
Charge with TC -15°C to 50°C -40°C to 71°C
Charge without TC 0°C to 40°C -15°C to 50°C
Terminal Torque Specifications
Terminal Type ft-lbs in-lbs Nm
AP | DT (AP) | M6 | M6M (stud) | TP07 (AP) | TP08 (AP) 4.2 - 6.0 50-70 5.6 - 7.9
FR45 6.0 - 7.5 70-90 7.9 - 10.1
M8 7.1 - 8.0 85-95 9.6 - 10.7
DT (stud) | M10M (stud) 9.2 - 10.4 110-125 12.2 - 14.0